zeige Details Cheung, P.., Lew, R.., ... SEC-viscometer detector systems. II. Resolution correction and determination of interdetector volume
in: Journal of Applied Polymer Science, in: Journal of Applied Polymer Science . - New York, NY [u.a.] : Wiley, ISSN 0021-8995, ZDB-ID 1491105-x Vol. 47 (9. 1993), p. 1701-1706
Zugang: zum Volltext
ähnliche Vorschläge
1993
The closely related topics of resolution correction and the determination of interdetector volume were examined. In determining the interdetector volume (δ) by searching to superimpose two types of intrinsic viscosity calibration curve (one from narrow standards and one from a broad standard), the underlying equation based upon symmetrical axial dispersion theory was derived. This equation combined with experimental results showed that the local intrinsic viscosity value is very similarly affected by interdetector volume and by band spreading. The result supported the idea of using an effective δ to effect an axial dispersion correction to local intrinsic viscosity data. However, it also increased the difficulty of finding both δ and standard deviation (δ) simultaneously by numerical search. Furthermore, attempts to apply the method to the chromatograms of narrow standards showed inadequate superposition. Following calculation of skewing factors, the superposition problems were attributed to skewing of the chromatograms of the monodisperse polymer standards used. © 1993 John Wiley & Sons, Inc.
Copyright: Copyright © 1993 John Wiley & Sons, Inc.
beteiligte Personen: Cheung, P.. , Lew, R.. , Balke, S. T.. , Mourey, T. H..
Format: Elektronisch
Sprache: English
Erschienen: 1993.
Serie: Wiley InterScience Backfile Collection 1832-2000 [Dig. Serial]
Schlagwörter:
URL: http://dx.doi.org/10.1002/app.1993.070470917

Ähnliche Vorschläge

Zurück zur geteilten Ansicht
Verfasser Titel Jahr
zeige Details Pigeon, Michael G.., Rudin, Alfred. Correction for interdetector volume in size exclusion chromatography (SEC)
in: Journal of Applied Polymer Science, in: Journal of Applied Polymer Science . - New York, NY [u.a.] : Wiley, ISSN 0021-8995, ZDB-ID 1491105-x Vol. 57 (3. 1995), p. 287-301
Zugang: zum Volltext
ähnliche Vorschläge
1995
zeige Details Lew, R.., Cheung, P.., ... SEC-viscometer detector systems. I. Calibration and determination of mark-houwink constants
in: Journal of Applied Polymer Science, in: Journal of Applied Polymer Science . - New York, NY [u.a.] : Wiley, ISSN 0021-8995, ZDB-ID 1491105-x Vol. 47 (9. 1993), p. 1685-1700
Zugang: zum Volltext
ähnliche Vorschläge
1993
zeige Details Suddaby, Kevin G.., Sanayei, Ramin A.., ... Multi-detector size-exclusion chromatography: a novel approach to calibration eliminating lag time estimation
in: Die Makromolekulare Chemie, in: Die Makromolekulare Chemie . - New York : Hüthig & Wepf Verlag, ISSN 0025-116X Vol. 194 (7. 1993), p. 1965-1974
Zugang: zum Volltext
ähnliche Vorschläge
1993
zeige Details Ouano, Augustus C.., Horne, Donald L.., ... Gel-permeation chromatography. IX. Instrumental design and computer interfacing of a GPC molecular weight detector system
in: Journal of Polymer Science: Polymer Chemistry Edition, in: Journal of Polymer Science: Polymer Chemistry Edition . - New York : John Wiley & Sons, Inc., ISSN 0360-6376 Vol. 12 (2. 1974), p. 307-322
Zugang: zum Volltext
ähnliche Vorschläge
1974
zeige Details Balke, S. T.., Mourey, T. H.., ... Number-average molecular weight by size exclusion chromatography
in: Journal of Applied Polymer Science, in: Journal of Applied Polymer Science . - New York, NY [u.a.] : Wiley, ISSN 0021-8995, ZDB-ID 1491105-x Vol. 51 (12. 1994), p. 2087-2102
Zugang: zum Volltext
ähnliche Vorschläge
1994